PC Strand

Original
price: Negotiable
minimum:
Total supply:
Delivery term: The date of payment from buyers deliver within days
seat: Beijing
Validity to: Long-term effective
Last update: 2017-12-28 01:44
Browse the number: 54
inquiry
Company Profile
 
 
Product details
We supply plain or ribbed PC Strand (pre-stressed concrete strand) material ranging from 2 wires, 3 wires, 7 wires and other sizes with high tensile strength and ductility. It's mainly used in civil construction, energy source sea transportation, and so on.

One PC Strand is made of three kinds of wires. The biggest one is in center, 9 smallest near it, 9 outside.
PC strand made of different wires increases its tensile strength greatly. It can be used for bridge or road structure.Pre-concrete strands are bound with straps in one big coil.
With high ductility PC (pre-concrete) strands are packed by straps in coils. PC strands are used in crane beams, floor slabs and stadiums.
Specification
Diameter: 4-20 mm.
Type: 1 × 2 strand, 1 × 3 strand, 1 × 7 strand, 1 × 19 strand.
Standard: ASTM A421-2002, GB/T 5223-2002, ASTM A648, BS 5896-1980, EN 14620 and BS 7777.
Material: high carbon steel.
Bending Times (180°) ≥ 4.
Technique data of high tensile PC (pre-stressed concrete) indented wire
No. Diameter Nominal tensile strength Nominal cross section Width of single rib Layer length Nominal mass Specified characteristic load Specified characteristic 0.1% proof load Load at 1% elongation
mm N/mm2 mm2 (ɑ/mm ) (c/mm) g/m kN kN kN
PCS-4 4 1670 12.6 0.90-1.30 24-30 98.9 21 17.5 17.9
1770 22.3 18.5 19
PCS-5 5 1670 19.6 1.30-1.70 28-36 154 32.7 27.2 21.8
1770 34.7 28.8 29.5
PCS-6 6 1670 28.3 1.60-2.00 30-40 222 47.3 39.9 40.2
1770 50.1 41.6 42.6
PCS-7 7 1570 38.5 1.80-2.00 35-45 302 60.4 50.1 51.3
1670 64.3 53.4 54.7
1 × 2 PC strand specifications
No. Nominal diameter Dn/mm Diameter tolerance mm Sectional area Sn/mm2 Reference quality per meter g/m Abstract tensile strength Rm/MPa not less than The largest force of the whole strand Fm/KN not less than Rated non-proportional extension force
PC-25 5 0.15 to -0.05 9.82 77.1 1570 15.4 13.9
1720 16.9 15.2
1860 18.3 16.5
1960 19.2 17.3
PC-258 5.8 13.2 104 1570 20.7 18.6
1720 22.7 20.4
1860 24.6 22.1
1960 25.9 23.3
PC-28 8 0.25 to -0.1 25.1 17 1470 36.9 33.2
1570 39.4 35.5
1720 43.2 38.9
1860 46.7 42
1960 49.2 44.3
PC-210 10 39.3 309 1470 57.8 52
1570 61.7 55.5
1720 67.6 60.8
1860 73.1 65.8
1960 77 69.3
PC-212 12 56.5 444 1470 83.1 74.8
1570 88.7 79.8
1720 97.2 87.5
1860 105 94.5
1 × 3 PC strand specification
No. Wire diameter mm Strand measurement mm Abstract tensile strength Rm/MPa not less than The largest force of the whole strand Fm/kN not less than Rated non-proportional extension force
PC-362 6.2 5.41 1570 31.1 28
1720 34.1 30.7
1860 36.8 33.1
1960 38.8 34.9
PC-365 6.5 5.6 1570 33.3 30
1720 36.5 32.9
1860 39.4 35.5
1960 41.6 37.4
PC-386 8.6 7.46 1470 55.4 49.9
1570 59.2 53.3
1720 64.8 58.3
1860 70.1 63.1
1960 73.9 66.5
PC-387 8.74 7.56 1570 60.6 54.5
1670 64.5 58.1
1860 71.8 64.6
PC-310 10.8 9.33 1470 86.6 77.9
1570 92.5 83.3
1720 101 90.9
1860 110 99
1960 115 104
PC-312 12.9 11.2 1470 125 113
1570 133 120
1720 146 131
1860 158 142
1960 166 149
1 × 7 PC strand specification
No. Nominal diameter Tensile strength Mass Cross sectional Area Minimum breaking strength Maximum breaking strength Yield strength at 0.1 % elongation
mm MPa g/m mm2 kN kN kN
PC-76 6.85 2060 220.2 28.2 58.1 66.8 51.1
PC-77 7 2060 234.3 30.0 61.8 71.1 54.4
PC-78 8 1860 296.8 38.0 70.7 81.3 60.8
PC-79 9.3 1860 406.1 52.0 96.7 111.0 83.2
9.6 1960 429.6 55.0 102.0 117.0 37.7
PC-711 11.3 1860 585.8 75.0 140.0 161.0 120.0
PC-712 12.5 1860 726.3 93.0 173.0 199.0 149.0
12.9 1860 781.0 100.0 186.0 214.0 160.0
PC-715 15.2 1770 1086.0 139.0 246.0 283.0 212.0
15.2 1860 1086.0 139.0 259.0 298.0 223.0
15.3 1770 1093.0 140.0 243.0 285.0 213.0
15.7 1770 1172.0 150.0 266.0 306.0 229.0
15.7 1860 1172.0 150.0 279.0 321.0 240.0
Note: Other sizes are also available.

Advantage
High tensile strength & low relaxation: Several wires combine together which makes the whole strand high tensile strength.
High bonding force & saving materials: Compared with single reinforced steel bar, PC strand reduces material 40% in mass with high bonding force.
Stability: It maintains toughness for a long time except in strong acid and alkali environment.
High corrosion & crack resistance: Because it's made with steel bars with coatings.
Better performance at high temperature: During processing, it's treated at high temperature after a significant load.
There are many big rolls of PC strands, outside packed with blue film and strips.
PC strands are packed in big coils with film and strips.PC strands are used in railway. Many people are working on it.
With high tensile strength and low relaxation, PC strands are used in railway.
Application
Thanks to the advantage of high tensile strength and corrosion resistance, PC strands are suitable for use in many areas, such as:
Civil construction: bridge structures industrial and factory buildings, road structures, poles, dams, crane beams, floor slabs, foundations, stadiums.
Air space: atomic reactor buildings, rock anchoring components.
Large concrete vessels: gas tanks, such as ethyl tank, LNG tank, LPG tank.
A big bridge is hang by many pieces of PC strands.
With the character of corrosion resistance and high tensile strength, PC strands make the suspension bridge beautiful and stable.Two people are building a flyover bridge with PC strands.
The PC strands can make the flyover bridge stable for a long time.
If you are interested can contact us via info@deformed-bar.com
Total0bar [View All]  Related Comments
 
more»Other products